            泄漏率對核通風系統高效空氣過濾器凈化系數的影響分析

            Influence of leakage rate on purification coefficient of high efficiency particulate air filters in nuclear ventilation systems

            王洪凱 陳榮添 陳慧慧
            福建福清核電有限公司

            摘要:

            推導了通風系統凈化系數與泄漏率及過濾器凈化系數的關系,認為核通風系統存在微小的泄漏會導致系統的凈化能力大為降低。以某核電廠為例,分析了通風系統泄漏的原因,并提出了降低泄漏率的措施。

            關鍵詞:通風系統,核電廠,泄漏率,凈化系數,高效空氣過濾器

            Abstract:

            Deduces the relationship between the purification coefficient of the ventilation system and the leakage rate and the purification coefficient of the filter material. Considers that small leakage of nuclear ventilation system will greatly reduce the purification capacity of the system. Taking a nuclear power plant as an example, analyses the leakage causes of the ventilation system and puts forward some measures to reduce the leakage rate.

            Keywords:ventilationsystem,nuclearpowerplant,leakagerate,purificationcoefficient,highefficiencyparticulateairfilter